Completely Eliminate and
Prevent Acid In Air Conditioning
& Refrigeration Systems!
Highside's Acid Neutralizer is designed to chemicaly
neutralize and prevent acids that are formed in air conditioning and refrigeration
systems due to refrigerant and refrigeration oil break down, moisture
and compressor burnout. Acid Neutralizer is recommended to prevent the
formation of acid and for systems that are showing signs of acid build
up or where a compressor burnout has occurred.
- No Solids or Solid residuals.
- Easy to Use, No Complicated Charts.
- Compatible With All Refrigerants.
- Compatible With All Lubricants.
- Works Fast, Circulates Quickly.
- Will Not Harm System Components.
- Can Prevent System Burnout.
Safe and Compatible In All Refrigerants,
Including CFC's, HFC's and HCFC's.
PREVENTIVE MAINTENANCE: When the use of an acid
test kit indicated no acid or low acid levels, Acid Neutralizer can be
used to prevent the formation of acid or neutralize existing acid by adding
one ounce of Acid Neutralizer for each 64 ounces of compressor oil.
MAINTENANCE & REPAIR: When acid related problems are evident or if
a test of the system shows acid is present at medium levels, Acid Neutralizer
can be used to neutralize existing acid by adding one ounce of Acid Neutralizer
for each 48 ounces of compressor oil.
BURNOUT CONDITION: Should high levels of acid be detected or if burnout
has occurred, Acid Neutralizer can be used to neutralize existing acid
by adding one ounce of Acid Neutralizer for each 24 ounces of compressor
oil. NOTICE: If burnout has occurred, follow standard industry practices
and change out the compressor. Install all recommended filter/driers then
evacuate and charge the system with the proper refrigerant.
Compatible with All Refrigeration Lubricants,
Including
Mineral Oil, Alkybenzene, Polyol Ester,
Polyalkylene Glycols, and Polyalphaolifins.
HOW TO ADD ACID NEUTRALIZER TO A SYSTEM.
1. Use a standard hand type oil pump to introduce
Acid Neutralizer in the high pressure (liquid line) side of a sealed system.
2. Acid Neutralizer can be added directly to
the oil in the compressor's crankcase prior to installing and charging
the system.
3. Using a standard manifold gauge, Acid Neutralizer
can be pushed into the low side of an operating system with refrigerant
or the pressure from the high side of the system.
·HIGHSIDE'S SYSTEM INJECTOR IS RECOMMENDED
FOR USE WITH ACID NEUTRALIZER·
RECOMMENDATIONS FOR CHARGING
ACID NEUTRALIZER
TO REFRIGERATION SYSTEMS
1.DETERMINE THE SYSTEM'S COMPRESSOR OIL VOLUME.
2.USE AN ACID TEST KIT TO ESTABLISH ACID LEVEL.
3.QUANTITY TO USE : Use at least one (1) ounce of Acid Neutralizer.
A. ZERO or LOW ACID LEVEL - Add one
(1) ounce of Acid Neutralizer for each sixty-four (64) ounces of compressor
oil volume.
B. MEDIUM ACID LEVEL - Add one (1) ounce of
Acid Neutralizer for each forty-eight (48) ounces of compressor oil
volume.
C. HIGH ACID LEVEL - Add one (1) one ounce
of Acid Neutralizer for each twenty-four (24) ounces of compressor oil
volume.
METHOD 1: HIGHSIDE'S SYSTEM INJECTOR.
Use with standard manifold gauge. Unscrew the
cap and fill the system injector to the top with Acid Neutralizer. Fill
completely so there is no trapped air. Tighten screw top. Connect the
system injector to the low side hose on manifold gauge. Connect low side
hose to the low side of the system and high side of the system and purge
lines. Slowly open valves on manifold gauge and with the high side pressure,
inject the Acid Neutralizer into the low side of the system.
METHOD 2: STANDARD CHARGING HOSES.
Place the proper amount of Acid Neutralizer in
a charging hose and connect one end to the low side access valve on the
compressor and the other end to a source of refrigerant. A 36" charging
hose holds 22ml or 3/4 ounces. Be sure hose is full to avoid any trapped
air. Make sure all fittings are tight. Open the valve at the refrigerant
source. Now with the source of the refrigerant above the access valve,
crack the access valve very slowly and force the Acid Neutralizer into
the system with refrigerant.
METHOD 3: STANDARD OIL CHARGING PUMP.
A standard hand operated oil charging pump can
be used to introduce Acid Neutralizer into a refrigeration system. Use
the oil pump to add the proper amount of Acid Neutralizer to the high
pressure ( liquid line ) side of the system. Be sure system is completely
turned off when using this method.
METHOD 4: ADD DIRECTLY TO THE COMPRESSOR OIL.
Acid Neutralizer can be added directly to the
refrigeration oil in the compressor's crankcase prior to installing and
charging the system. Avoid prolonged exposure to air as most new refrigeration
oils and Acid Neutralizer are very hygroscopic.
- ALWAYS determine the compressor's oil volume
before preceding.
- ALWAYS add Acid Neutralizer to a system very
slowly
- ALWAYS use at least one (1) ounce of Acid
Neutralizer.
- ALWAYS keep Acid Neutralizer and refrigeration
oils tightly closed. Avoid contamination.
OK TO EXCEED RECOMMENDED AMOUNTS
EXCEEDING THE RECOMMENDED AMOUNT OF ACID NEUTRALIZER
WILL NOT HARM AIR CONDITIONING OR REFRIGERATION SYSTEMS AS LONG AS THE
AMOUNT OF ACID NEUTRALIZER USED IS NOT MORE THAN 10% OF THE COMPRESSOR'S
TOTAL OIL VOLUME.
|